Products

Terrasat 125 Watt C Band IBUC R

Terrasat 125 Watt C Band IBUC R

Description

The Terrasat IBUC R has all of the IBUC advanced features and reliability as well as the upgraded RJ45 M&C Connector.

 

IBUC offers significant benefits:

  • Low Terminal Cost
  • Simple design and installation
  • Simplified 1+1 configuration
  • Superior RF performance

 

The IBUC R comes with a complete set of diagnostic tools including:

  • 10 MHz input detector
  • Input voltage and current monitoring
  • Transmit L-band input level detector
  • Transmit RF output level detector
  • User configurable thresholds and alarms

 

  • 125 Watt Output Power @ P1dB
  • Multiple Frequency Options Available
Frequency range
Band 1 Std C-Band
External reference
IBUC
5850 to 6425 MHz
950 to 1525 MHz
Band 2 Palapa/ST-1
External reference
IBUC
6425 to 6725 MHz
975 to 1275 MHz
Band 3 Insat
External reference
IBUC
6725 to 7025 MHz
1150 to 1450 MHz
Band 4 Ext. C-Band
External reference
IBUC
5850 to 6650 MHz
950 to 1750 MHz
Band 5 Full C-Band
External reference
IBUC
5850 to 6725 MHz
975 to 1850 MHz
Band 6 S-Ext C, 80-150W
External reference
IBUC
5725 to 6525 MHz
1075 to 1875 MHz
Input
VSWR / Impedance 1.5:1 max / 50 Ohm
Input Connector Type N female (50 Ohm)
Input Connector options Type F (75 Ohm), TNC (50 Ohm)
Input power detector -55 to –20 dBm
Gain
Small Signal Gain (L-band to RF) with attenuator set to 0 dB
80W 80 dB min
100W 81 dB min
125W 82 dB min
150W 83 dB min
175W 83 dB min
200W 84 dB min
Attenuator range 30 dB variable in 0.1 dB steps
RF Output
Interface CPR-137G
VSWR 1.5:1 max
Rated output power (P1dB)
80W +49 dBm min
100 W +50 dBm min
125 W +51 dBm min
150 W +51.8 dBm min
175 W +52.4 dBm min
200 W +53 dBm min
Note: output power in bands 4 & 5 is reduced by 0.5 dB.
IMD3 (2 carriers, 3 dB TOBO) -27 dBc max
Level stability with ALC +0.5 dB
Output power detector range Rated power to –20 dB
Power reading accuracy + 1.0 dB max.
Harmonics -50 dBc max.
Output Noise Power Density
TX < -74 dBm/Hz
RX < -145 dBm/Hz
SSB Phase Noise
10 Hz
External reference
IBUC
-115 dBc/Hz
-54 dBc/Hz
100 Hz
External reference
IBUC
-140 dBc/Hz
-79 dBc/Hz
1 kHz
External reference
IBUC
-150 dBc/Hz
-89 dBc/Hz
10 kHz
External reference
IBUC
-155 dBc/Hz
-94 dBc/Hz
100 kHz
External reference
IBUC
N/A
-100 dBc/Hz
1 MHz
External reference
IBUC
N/A
-110 dBc/Hz
External Reference (multiplexed on TX I FL)
Frequency 10 MHz
Level -12 to +5 dBm
Internal Reference – optional
Local Oscillator Frequency
Band 1
Inverting
Non-inverting
7375 MHz
4900 MHz
Band 2
Inverting
Non-inverting
7700 MHz
n/a
Band 3
Inverting
Non-inverting
8175 MHz
n/a
Band 4
Inverting
Non-inverting
7600 MHz
4900 MHz
Band 5
Inverting
Non-inverting
7700 MHz
4900 MHz
Band 6
Inverting
Non-inverting
7600 MHz
n/a
Monitor and Control
Ethernet (HTTP , Telnet, SNMP ), via RJ45 connector,
RS232/485, Hand-held Terminal via MS-type connector,
FSK multiplexed on TX I FL.
Environmental
Operating temperature -40oC to +55oC
Relative humidity 100% condensing
Altitude 10,000 ft., (3,000 m) ASL
(View our PDF Datasheet for more information)